Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Codas ; 35(2): e20210143, 2023.
Artigo em Português, Inglês | MEDLINE | ID: mdl-37098938

RESUMO

PURPOSE: Estimate the reproducibility of hearing screening results using the uHear™ smartphone-based app in two response modes: self-test response and test-operator. METHODS: Reliability study conducted with 65 individuals aged ≥18 years assisted at the Speech-language and Hearing Therapy clinic of a public higher-education institution. Hearing screening was conducted by a single researcher using the uHear app and earbud headphones in a soundproof booth. Participants responded to sound stimuli in both self-test response mode and test-operator mode. The order in which these two uHear test modes were applied was altered according to the entrance of each participant in the study. The correspondence between the hearing thresholds obtained from each response mode was analyzed and their Intraclass Correlation Coefficient (ICC) was estimated. RESULTS: A correspondence of ±5 dBHL >75% was observed between these hearing thresholds. The ICC values showed excellent agreement between the two response modes at all frequencies >40 dBHL tested. CONCLUSION: The two hearing screening response modes using the uHear app presented high reproducibility, suggesting that the test-operator mode is a viable alternative when the self-test response mode is not recommended.


OBJETIVO: Estimar a reprodutibilidade dos resultados da triagem auditiva com o aplicativo uHear, utilizando dois diferentes modos de resposta, o modo autoaplicado e o modo com intermediação do pesquisador. MÉTODO: Estudo de confiabilidade realizado com 65 indivíduos, maiores de 18 anos, que compareceram à clínica escola de Fonoaudiologia de uma instituição pública de ensino superior. A triagem auditiva foi realizada com o aplicativo uHear, em cabina acústica, utilizando fone intra-auricular e conduzida sempre pelo mesmo pesquisador. Os participantes responderam ao estímulo sonoro de maneira autoaplicada e com intermediação do pesquisador. A ordem de realização dos dois modos de resposta ao aplicativo uHear foi alternada de acordo com a entrada do participante no estudo. Foi analisada a correspondência entre os limiares auditivos obtidos com os dois modos de resposta, bem como estimado o Coeficiente de Correlação Intraclasse (ICC). RESULTADOS: Verificou-se uma correspondência de ± 5 dBNA superior a 75% entre os limiares auditivos obtidos nos dois modos de resposta. O ICC revelou concordância excelente entre os dois modos de resposta, em todas as frequências testadas, para intensidades superiores a 40 dBNA. CONCLUSÃO: Os dois modos de resposta à triagem auditiva com o aplicativo uHear apresentam elevada reprodutibilidade, o que permite indicar o modo de resposta com intermediação do pesquisador como uma alternativa viável quando o modo autoaplicado não for recomendado.


Assuntos
Aplicativos Móveis , Humanos , Adolescente , Adulto , Reprodutibilidade dos Testes , Smartphone , Audição , Testes Auditivos/métodos , Audiometria de Tons Puros/métodos
2.
CoDAS ; 35(2): e20210143, 2023. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1430236

RESUMO

RESUMO Objetivo Estimar a reprodutibilidade dos resultados da triagem auditiva com o aplicativo uHear, utilizando dois diferentes modos de resposta, o modo autoaplicado e o modo com intermediação do pesquisador. Método Estudo de confiabilidade realizado com 65 indivíduos, maiores de 18 anos, que compareceram à clínica escola de Fonoaudiologia de uma instituição pública de ensino superior. A triagem auditiva foi realizada com o aplicativo uHear, em cabina acústica, utilizando fone intra-auricular e conduzida sempre pelo mesmo pesquisador. Os participantes responderam ao estímulo sonoro de maneira autoaplicada e com intermediação do pesquisador. A ordem de realização dos dois modos de resposta ao aplicativo uHear foi alternada de acordo com a entrada do participante no estudo. Foi analisada a correspondência entre os limiares auditivos obtidos com os dois modos de resposta, bem como estimado o Coeficiente de Correlação Intraclasse (ICC). Resultados Verificou-se uma correspondência de ± 5 dBNA superior a 75% entre os limiares auditivos obtidos nos dois modos de resposta. O ICC revelou concordância excelente entre os dois modos de resposta, em todas as frequências testadas, para intensidades superiores a 40 dBNA. Conclusão Os dois modos de resposta à triagem auditiva com o aplicativo uHear apresentam elevada reprodutibilidade, o que permite indicar o modo de resposta com intermediação do pesquisador como uma alternativa viável quando o modo autoaplicado não for recomendado.


ABSTRACT Purpose Estimate the reproducibility of hearing screening results using the uHear™ smartphone-based app in two response modes: self-test response and test-operator. Methods Reliability study conducted with 65 individuals aged ≥18 years assisted at the Speech-language and Hearing Therapy clinic of a public higher-education institution. Hearing screening was conducted by a single researcher using the uHear app and earbud headphones in a soundproof booth. Participants responded to sound stimuli in both self-test response mode and test-operator mode. The order in which these two uHear test modes were applied was altered according to the entrance of each participant in the study. The correspondence between the hearing thresholds obtained from each response mode was analyzed and their Intraclass Correlation Coefficient (ICC) was estimated. Results A correspondence of ±5 dBHL >75% was observed between these hearing thresholds. The ICC values showed excellent agreement between the two response modes at all frequencies >40 dBHL tested. Conclusion The two hearing screening response modes using the uHear app presented high reproducibility, suggesting that the test-operator mode is a viable alternative when the self-test response mode is not recommended.

3.
Epidemiol Serv Saude ; 30(2): e2020607, 2021.
Artigo em Inglês, Português | MEDLINE | ID: mdl-34076209

RESUMO

OBJECTIVE: To investigate factors associated with the notification of noise-induced hearing loss (NIHL), on the Notifiable Health Conditions Information System (SINAN) in Brazil. METHODS: This was an ecological study to estimate the proportion of municipalities that had notified NIHL. Logistic regression models were used to identify associated factors. RESULTS: Between 2013-2015, 277 (5.0%) municipalities notified NIHL. Notification was more prevalent among municipalities in an Occupational Health Referral Center (CEREST) coverage area (OR=1.62 - 95%CI 1.02;2.59) or those that had a CEREST in their territory (OR=4.37 - 95CI% 2.75;6.93), those that were closer to the state capital (OR=1.43 - 95%CI 1.06;1.92) and those with a high human development index (OR=2.35 - 95%CI 1.16;4.75). Among the municipalities located in a CEREST coverage area, notification was more frequent when there was a speech-language-hearing professional in the team (OR=1.96 - 95%CI - 1.47;2.63) and when employee turnover was low (OR=1.88 - 95%CI 1.40;2.52). CONCLUSION: Contextual factors influence NIHL notification, particularly the presence of CERESTs and their qualification.


Assuntos
Perda Auditiva Provocada por Ruído , Ruído Ocupacional , Saúde Ocupacional , Brasil/epidemiologia , Perda Auditiva Provocada por Ruído/epidemiologia , Humanos , Sistemas de Informação , Ruído Ocupacional/efeitos adversos
4.
Preprint em Português | SciELO Preprints | ID: pps-1924

RESUMO

Objective: To investigate factors associated with the notification of noise-induced hearing loss (NIHL) in Brazil's Notifiable Diseases Information System. Methods: Ecological study to estimate the proportion of municipalities that notified NIHL. Logistic regression models were conducted to identify associated factors. Results: Between 2013-2015, 277 (5.0%) municipalities notified NIHL. This notification was more common among municipalities with coverage by a Worker Health Referral Centre (CEREST) (OR=1.62 ­ 95%CI 1.02;2.59) or that hosted a CEREST in their territory (OR=4.37 ­ 95CI% 2.75;6.93), within a shorter distance to the state capital (OR=1.43 ­ 95%IC 1.06;1.92) and having a high human development index (OR=2.35 ­ 95%CI 1.16;4.75). Among the municipalities located in a Cerest coverage area, notification was more common when there was a Speech-Language-Hearing professional in the team (OR=1.96 ­ 95%CI ­ 1.47;2.63) and a low turnover of professionals (OR=1.88 ­ 95%CI 1.40;2.52). Conclusion: Contextual factors influence NIHL notification, particularly the existence and qualification of CEREST. 


Objetivo: Investigar fatores associados à notificação de perda auditiva induzida por ruído (Pair) no Sistema de Informação de Agravos de Notificação no Brasil. Métodos: Estudo ecológico para estimar a proporção de municípios notificantes de Pair. Foram empregados modelos de regressão logística para identificar fatores associados. Resultados: Entre 2013 e 2015, 277 (5,0%) municípios notificaram Pair. A notificação foi mais comum entre municípios com cobertura por Cerest (OR=1,62 ­ IC95% 1,02;2,59) ou que sediavam unidade de Cerest em seu território (OR=4,37 ­ IC95% 2,75;6,93), a menor distância da capital do estado (OR=1,43 ­ IC95% 1,06;1,92) e com alto índice de desenvolvimento humano (OR=2,35 ­ IC95% 1,16;4,75). Entre os municípios situados em área com cobertura de Cerest, a notificação foi mais comum quando na equipe havia fonoaudiólogo (OR=1,96 ­ IC95% 1,47;2,63) e era baixa a rotatividade de profissionais (OR=1,88 ­ IC95% 1,40;2,52). Conclusão: Fatores contextuais influenciam na notificação de Pair, notadamente a existência e qualificação dos Cerest.

5.
Epidemiol. serv. saúde ; 30(2): e2020607, 2021. tab, graf
Artigo em Inglês, Português | LILACS | ID: biblio-1249801

RESUMO

Objetivo: Investigar fatores associados à notificação de perda auditiva induzida por ruído (Pair), no Sistema de Informação de Agravos de Notificação no Brasil. Métodos: Estudo ecológico para estimar a proporção de municípios notificantes de Pair. Foram empregados modelos de regressão logística para identificar fatores associados. Resultados: Entre 2013 e 2015, 277 (5,0%) municípios notificaram Pair. A notificação foi mais comum entre municípios com cobertura por Cerest (OR=1,62 - IC95% 1,02;2,59) ou que sediavam unidade de Cerest em seu território (OR=4,37 - IC95% 2,75;6,93), a menor distância da capital do estado (OR=1,43 - IC95% 1,06;1,92) e com alto índice de desenvolvimento humano (OR=2,35 - IC95% 1,16;4,75). Entre os municípios situados em área com cobertura de Cerest, a notificação foi mais comum quando na equipe havia fonoaudiólogo (OR=1,96 - IC95% 1,47;2,63) e era baixa a rotatividade de profissionais (OR=1,88 - IC95% 1,40;2,52). Conclusão: Fatores contextuais influenciam na notificação de Pair, notadamente a existência e qualificação dos Cerest.


Objetivo: Investigar factores asociados con la notificación de pérdida auditiva inducida por ruido (Pair) en el Sistema de Información de Agravamientos de Notificación Obligatoria en Brasil. Métodos: Estudio ecológico para estimar la proporción de municipios notificantes de Pair. Se utilizaron modelos de regresión logística para identificar factores asociados. Resultados: Entre 2013-2015, 277 (5,0%) municipios notificaron Pair. La notificación fue más común entre los municipios con cobertura de los Centros de Referencia en Salud Ocupacional (Cerest) (OR=1,62 - IC95% 1,02; 2,59), o que albergaron Cerest (OR=4,37 - IC95% 2,75; 6,93), cercanos a la capital (OR=1,43 - IC95% 1,06; 1,92) y con alto índice de desarrollo humano (OR=2,35 - IC95% 1,16; 4,75). Entre los municipios en área de cobertura de Cerest, la notificación fue más alta cuando había fonoaudiólogo en el equipo (OR=1,96 - IC95% 1,47; 2,63) y baja rotación de profesionales (OR=1,88 - IC95% 1,40; 2,52). Conclusión: Factores contextuales influyen en la notificación de Pair, en particular, la existencia y cualificación de los Cerest.


Objective: To investigate factors associated with the notification of noise-induced hearing loss (NIHL), on the Notifiable Health Conditions Information System (SINAN) in Brazil. Methods: This was an ecological study to estimate the proportion of municipalities that had notified NIHL. Logistic regression models were used to identify associated factors. Results: Between 2013-2015, 277 (5.0%) municipalities notified NIHL. Notification was more prevalent among municipalities in an Occupational Health Referral Center (CEREST) coverage area (OR=1.62 - 95%CI 1.02;2.59) or those that had a CEREST in their territory (OR=4.37 - 95CI% 2.75;6.93), those that were closer to the state capital (OR=1.43 - 95%CI 1.06;1.92) and those with a high human development index (OR=2.35 - 95%CI 1.16;4.75). Among the municipalities located in a CEREST coverage area, notification was more frequent when there was a speech-language-hearing professional in the team (OR=1.96 - 95%CI - 1.47;2.63) and when employee turnover was low (OR=1.88 - 95%CI 1.40;2.52). Conclusion: Contextual factors influence NIHL notification, particularly the presence of CERESTs and their qualification.


Assuntos
Humanos , Saúde Ocupacional/normas , Perda Auditiva Provocada por Ruído/epidemiologia , Ruído Ocupacional/efeitos adversos , Brasil/epidemiologia , Sistemas de Informação , Vigilância em Saúde Pública
6.
Rev. CEFAC ; 20(6): 723-733, Nov.-Dec. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-976895

RESUMO

ABSTRACT Purpose: to investigate the presence of Speech-Language and Hearing (SLH) professionals in the teams of Workers' Health Reference Centres (Centros de Referência em Saúde do Trabalhador - CEREST) in Brazil, their distribution and features related to inclusion and activities. Methods: a descriptive, epidemiological study, in which all the CERESTs in the country were units of observation. Primary data were collected by applying a questionnaire to the CEREST Coordinator or one of their designated representatives. Results: 158 of the 199 eligible CERESTs participated in the research. In 2014, 48.1% of these CEREST had an SLH professional on their team, with the highest number in the Southeast and the lowest in the North Region. When present, statutory contracts were the most common form of employment. Approximately 75% of the CEREST with a SLH professional in the team reported surveillance activities in general, as well as actions specific to noise-induced hearing loss and work-related voice disorders. However, in 7.9% of these units, the SLH professionals were exclusively dedicated to clinical care. Conclusion: this study describes and examines the incipient inclusion of SLH professionals in CEREST, providing evidence that indicates regional inequalities and reveals that, despite generally working in health surveillance activities, there remain units where the SLH professionals are only dedicated to specialized care.


RESUMO Objetivo: investigar a presença do fonoaudiólogo na equipe dos Centros de Referência em Saúde do Trabalhador (Cerest) do Brasil, sua distribuição e características de sua inserção e das ações desenvolvidas. Métodos: estudo epidemiológico descritivo que teve como unidades de observação todos os Cerest do País. Dados primários foram coletados por meio da aplicação de questionário ao coordenador do Cerest ou a um representante designado. Resultados: dos 199 Cerest elegíveis para a pesquisa, 158 participaram. Em 2014, 48,1% dos Cerest tinham fonoaudiólogo na equipe, em maior proporção no Sudeste e menor no Norte do País. Quando presente, o vínculo de servidor estatutário foi o mais comum. Ações de vigilância em geral, assim como as específicas para perda auditiva induzida por ruído e distúrbios de voz relacionados ao trabalho, foram referidas por aproximadamente 75% dos Cerest com fonoaudiólogo. Mas em 7,9% dessas unidades, o fonoaudiólogo se dedicava exclusivamente ao atendimento clínico. Conclusão: o presente estudo descreve e problematiza a incipiente inserção do fonoaudiólogo nos Cerest, contribui com evidências que indicam desigualdades regionais e revela que, apesar da sua atuação geralmente incluir ações de vigilância em saúde, ainda há unidades onde o fonoaudiólogo se dedica apenas à assistência especializada.

7.
Rev. CEFAC ; 20(3): 353-362, May-June 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-956505

RESUMO

ABSTRACT Objective: to investigate the evolution and estimate the shortage of Speech, Language and Hearing professionals in Primary Health Care between 2005 and 2015. Methods: a mixed ecological study using data from the National Registry of Health Facilities and the Primary Health Care Information System. A descriptive analysis regarding the evolution of the number of professionals working in Primary Health Care over this period, in Brazilian states and regions, was conducted. The ratio of professionals per 100,000 inhabitants for the years 2005, 2010 and 2015, and the shortages in 2015, were estimated. Results: in 2005, there were 1,717 professionals working in Primary Health Care, that is, one per 100,000 inhabitants. In 2015, there were 4,124, increasing to 2.1/100,000. In 2015, the shortage in supply was 55.1%, varying widely across the states. Conclusion: the shortage in supply is equivalent to an absence of Speech, Language and Hearing service coverage within Primary Health Care for more than half of the Brazilian population. It is worth noting that a conservative parameter was adopted to conduct this estimate. The results suggest a process of consolidation for the inclusion of Speech, Language and Hearing professionals within Primary Health Care, however, still characterized by insufficient and unequal supply across the nation.


RESUMO Objetivo: investigar a evolução e estimar o déficit da oferta da Fonoaudiologia na Atenção Básica entre 2005-2015. Métodos: neste estudo ecológico misto, foram utilizados dados do Cadastro Nacional de Estabelecimentos em Saúde e do Sistema de Informação da Atenção Básica para análise descritiva da evolução do número de fonoaudiólogos na Atenção Básica, por Unidade da Federação e região. Foi estimada a razão de fonoaudiólogos por 100.000 habitantes para os anos de 2005, 2010 e 2015 e o déficit da oferta desses profissionais em 2015. Resultados: em 2005 havia 1.717 fonoaudiólogos na Atenção Básica, correspondendo à oferta de um profissional por 100.000 habitantes. Em 2015, havia 4.124 fonoaudiólogos, elevando a oferta para 2,1/100.000. Identificou-se déficit de 55,1% na oferta de fonoaudiólogos em 2015, variando entre as Unidades da Federação. Conclusão: o déficit da oferta equivale à ausência de cobertura dos serviços em Fonoaudiologia na Atenção Básica para mais da metade da população brasileira. Deve-se ressaltar que para essa estimativa, um parâmetro conservador foi adotado como pressuposto. Os resultados sugerem um processo de consolidação da inserção do fonoaudiólogo na Atenção Básica, porém ainda caracterizado por uma oferta insuficiente e desigual no território nacional.

8.
Artigo em Inglês, Português | MEDLINE | ID: mdl-26487294

RESUMO

OBJECTIVE: To analyze whether sociodemographic, occupational, and health-related data are associated with the use of hearing protection devices at work, according to gender. METHODS: A cross-sectional study was conducted in 2006, using a random sample of 2,429 workers, aged between 18 and 65 years old, from residential sub-areas in Salvador, BA, Northeastern Brazil. Questionnaires were used to obtain sociodemographic, occupational, and health-related data. Workers who reported that they worked in places where they needed to shout in order to be heard were considered to be exposed to noise. Exposed workers were asked whether they used hearing protection devices, and if so, how frequently. Analyses were conducted according to gender, with estimates made about prevalence of the use of hearing protection devices, prevalence ratios, and their respective 95% confidence intervals. RESULTS: Twelve percent (12.3%) of study subjects reported that they were exposed to noise while working. Prevalence of the use of hearing protection devices was 59.3% for men and 21.4% for women. Men from higher socioeconomic levels (PR = 1.47; 95%CI 1.14;1.90) and who had previous audiometric tests (PR = 1.47; 95%CI 1.15;1.88) were more likely to use hearing protection devices. For women, greater perceived safety was associated with the use of protection devices (PR = 2.92; 95%CI 1.34;6.34). This perception was specifically related to the presence of supervisors committed to safety (PR = 2.09; 95%CI 1.04;4.21), the existence of clear rules to prevent workplace injuries (PR = 2.81; 95%CI 1.41;5.59), and whether they were informed about workplace safety (PR = 2.42; 95%CI 1.23;4.76). CONCLUSIONS: There is a gender bias regarding the use of hearing protection devices that is less favorable to women. The use of such devices among women is positively influenced by their perception of a safe workplace, suggesting that gender should be considered as a factor in hearing conservation programs.


Assuntos
Dispositivos de Proteção das Orelhas/estatística & dados numéricos , Perda Auditiva Provocada por Ruído/prevenção & controle , Ruído Ocupacional/prevenção & controle , Doenças Profissionais/prevenção & controle , Adolescente , Adulto , Idoso , Brasil , Estudos Transversais , Feminino , Testes Auditivos , Humanos , Masculino , Pessoa de Meia-Idade , Percepção , Fatores Sexuais , Fatores Socioeconômicos , Inquéritos e Questionários , Local de Trabalho , Adulto Jovem
9.
Artigo em Inglês | LILACS | ID: biblio-962173

RESUMO

OBJECTIVE To analyze whether sociodemographic, occupational, and health-related data are associated with the use of hearing protection devices at work, according to gender. METHODS A cross-sectional study was conducted in 2006, using a random sample of 2,429 workers, aged between 18 and 65 years old, from residential sub-areas in Salvador, BA, Northeastern Brazil. Questionnaires were used to obtain sociodemographic, occupational, and health-related data. Workers who reported that they worked in places where they needed to shout in order to be heard were considered to be exposed to noise. Exposed workers were asked whether they used hearing protection devices, and if so, how frequently. Analyses were conducted according to gender, with estimates made about prevalence of the use of hearing protection devices, prevalence ratios, and their respective 95% confidence intervals. RESULTS Twelve percent (12.3%) of study subjects reported that they were exposed to noise while working. Prevalence of the use of hearing protection devices was 59.3% for men and 21.4% for women. Men from higher socioeconomic levels (PR = 1.47; 95%CI 1.14;1.90) and who had previous audiometric tests (PR = 1.47; 95%CI 1.15;1.88) were more likely to use hearing protection devices. For women, greater perceived safety was associated with the use of protection devices (PR = 2.92; 95%CI 1.34;6.34). This perception was specifically related to the presence of supervisors committed to safety (PR = 2.09; 95%CI 1.04;4.21), the existence of clear rules to prevent workplace injuries (PR = 2.81; 95%CI 1.41;5.59), and whether they were informed about workplace safety (PR = 2.42; 95%CI 1.23;4.76). CONCLUSIONS There is a gender bias regarding the use of hearing protection devices that is less favorable to women. The use of such devices among women is positively influenced by their perception of a safe workplace, suggesting that gender should be considered as a factor in hearing conservation programs.


OBJETIVO Analisar se dados sociodemográficos, ocupacionais e de saúde estão associados ao uso de equipamento de proteção auditiva no trabalho, segundo gênero. MÉTODOS Estudo transversal com amostra aleatória de 2.429 trabalhadores de 18 a 65 anos de subáreas de base domiciliar em Salvador, BA, no ano de 2006. Foram aplicados questionários para obtenção de dados sociodemográficos, ocupacionais e de saúde. Foram considerados expostos ao ruído aqueles que relataram trabalhar em local onde era necessário gritar para ser ouvido. Os trabalhadores expostos foram questionados sobre uso e regularidade do uso de equipamento de proteção auditiva. A análise foi conduzida por gênero, estimando-se a prevalência do uso do equipamento de proteção auditiva, razões de prevalência e os respectivos intervalos de 95% de confiança. RESULTADOS Entre os participantes do estudo, 12,3% referiram trabalhar expostos ao ruído. A prevalência do uso do equipamento de proteção auditiva foi 59,3% e 21,4%, para homens e mulheres, respectivamente. Entre os homens, maior nível socioeconômico (RP = 1,47; IC95% 1,14;1,90) e ter realizado audiometria (RP = 1,47; IC95% 1,15;1,88) foram fatores associados ao uso do equipamento. Entre as mulheres, a percepção de maior segurança associou-se ao uso do equipamento (RP = 2,92; IC95% 1,34;6,34). Essa percepção deveu-se, especialmente, à presença de supervisores comprometidos com a segurança (RP = 2,09; IC95% 1,04;4,21), à existência de regras claras para evitar acidentes de trabalho (RP = 2,81; IC95% 1,41;5,59) e ao recebimento de informações sobre segurança no trabalho (RP = 2,42; IC95% 1,23;4,76). CONCLUSÕES Há um viés de gênero em relação ao uso do equipamento de proteção auditiva menos favorável às mulheres em comparação com os homens. O uso do equipamento entre mulheres é influenciado positivamente pela percepção de um ambiente de trabalho seguro, sugerindo que o gênero precisa ser considerado nos programas de conservação auditiva.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Idoso , Adulto Jovem , Dispositivos de Proteção das Orelhas/estatística & dados numéricos , Perda Auditiva Provocada por Ruído/prevenção & controle , Ruído Ocupacional/prevenção & controle , Doenças Profissionais/prevenção & controle , Percepção , Fatores Socioeconômicos , Brasil , Fatores Sexuais , Estudos Transversais , Inquéritos e Questionários , Local de Trabalho , Testes Auditivos , Pessoa de Meia-Idade
10.
Rev. CEFAC ; 15(5): 1364-1370, set.-out. 2013. tab
Artigo em Português | LILACS | ID: lil-694090

RESUMO

A exposição ao ruído no trabalho é o fator de risco modificável mais importante para a perda auditiva em adultos. Na indústria de transformação, a exposição a níveis elevados de pressão sonora afeta um grande número de trabalhadores. As normas brasileiras estabelecem como obrigatório, para todas as empresas, o monitoramento do ruído ocupacional e da condição auditiva dos trabalhadores, assim como garantias para a proteção do trabalhador. No entanto, a aplicação das normas é frágil e pouco se sabe sobre a distribuição de exposição ao ruído no País. Este estudo tem como objetivo investigar e sumarizar a distribuição da exposição ao ruído e do uso do equipamento de proteção auditiva entre trabalhadores da indústria de transformação no Brasil. A menor prevalência de exposição ao ruído dentre os ramos da indústria da transformação é de 45% e poucos são os dados sobre o uso do equipamento de proteção auditiva entre os trabalhadores expostos. Comparando-se os disponíveis para os diferentes ramos de atividade, a exposição ao ruído alcança níveis mais altos no ramo da fabricação de produtos de madeira, onde também se observa a menor proporção de uso do equipamento de proteção auditiva. A escassez de dados sobre as condições de trabalho, exposição ao ruído e proteção auditiva, limita os esforços em fazer com que a saúde auditiva seja incluída entre as prioridades da saúde pública no Brasil.


Occupational noise exposure is the most important modifiable risk factor for hearing loss in adults. The manufacturing industry has elevated levels of noise exposure that affect a large number of workers. The Brazilian norms state that noise and hearing function must be monitored, along with safeguards to protect workers, these are compulsory for all companies. However norms enforcement is weak and little is known about noise exposure distribution in the country. The purpose of this study is to investigate and summarize the distribution of noise exposure and use of hearing protection devices among workers in the manufacturing industry in Brazil. Among the manufacturing industry trends the minimum prevalence of noise exposure is 45%, and there are only a few data on the use of hearing protection device against hearing loss. Comparing available data from different industry trades, levels of noise exposure are higher in the logging and wood processing industry, together with a lower proportion of hearing protection device usage. The lack of data on work conditions, noise exposure and hearing protection limits the strength of hearing health among public health priorities in Brazil.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...